System Overview and Main Attributes
What is Bauder LiquiTEC Balcony, Walkway & Terrace System?
The Bauder LiquiTEC Balcony, Walkway & Terrace System combines catalyst activated PMMA based liquid resins and polyester reinforcement fleece to form a fast curing, tough and durable waterproofing / surfacing membrane, which can be used in both new build and refurbishment applications over a variety of substrates and existing waterproofing materials.
Three main variants are available;
- A reinforced system with wearing surface, for use where the area to be treated is above occupied premises.
- An unreinforced system with wearing surface, for applications such as cantilever balconies.
- A reinforced system without wearing surface, for all buried applications (e.g. under tiles, paving, timber decking etc.).
System Components
LiquiPRIME 1 (if required) – resin for priming timber and asphalt.
LiquiPRIME 2 (if required) – resin for priming cementitious materials, brickwork and blockwork etc.
LiquiPASTE (if required) – resin for repairing cracks and holes in the substrate.
Bauder PMMA Cleaner – for cleaning metal and plastic substrates, re-activating previously applied resin and cleaning tools.
LiquiDETAIL – resin for waterproofing upstands and details.
LiquiFIBRE – resin for waterproofing awkward shapes and areas where access is restricted.
LiquiBALKON (if required) – resin for waterproofing main flat areas.
Bauder 110g Reinforcement Fleece – reinforcement fleece for LiquiBALKON and LiquiDETAIL.
LiquiPAVE RF – hard-wearing bedding layer for Bauder Quartz.
Catalyst – powder to be added to resins prior to application.
Bauder Quartz – broadcast aggregate providing the wearing layer.
LiquiFINISH – finish coat resin available in Blue Grey (RAL 7031), Traffic Grey (RAL 7043) and Stone Grey (RAL 7030).
Liquid Thixo (if required) – additive for LiquiPRIME and LiquiFINISH applications on high upstands.
The resins are packaged in re-sealable metal containers which will be supplied separately or on pallets.
What is PMMA?
PMMA is an abbreviation for Poly Methyl Methacrylate. MMA was first synthesised in 1903, with the first practical and commercial applications coming in the early 1930’s.
The resins and systems were designed to be:
- Impact resistant
- Abrasion resistant and resistant to mechanical wear
- Impermeable to liquids
- Hygienically safe
- Highly durable
- Resistant to chemicals and weathering
- Non-sensitive to humidity
- Easy to overcoat
- Variable in colour and design characteristics
- Usable over a wide temperature range
PMMA roofing systems now have a greater than 25 year track record.
Why Use a Reinforcement Fleece?
Whatever the elastomeric properties, any unreinforced, fully bonded liquid applied material will have difficulty in bridging unforeseen cracks.

The unique elastomeric waterproofing resins, LiquiDETAIL and LiquiBALKON, in conjunction with the special Bauder 110g reinforcement fleece provides the system with exceptional long-term resistance to regular and unforeseen movement and exceptional resistance to flexural fatigue.
The Bauder 110g reinforcement fleece helps the system achieve:
- Tensile Strength: c.a 6.50 N/mm²
- Inter Layer Adhesion: c.a 3.30 N/mm²
- Adhesion to Substrate: min 0.80 N/mm², max 2.50 N/mm²

The Bauder LiquiTEC Balcony, Walkway & Terrace System is suitable for both New Build and Refurbishment applications. It can be applied directly onto concrete / screeded decks and can also be applied to existing asphalt waterproofing.
Substrate Assessment
- Ensure that the structure is designed to withstand the proposed loadings.
- Any existing known structural defects must be rectified prior to overlay.
- Concrete structures should be designed in accordance with BS8110/CP110.
- Timber / plywood decks must be constructed from minimum 15mm exterior grade plywood, with joists at max 450mm centres and minimum 18mm for up to 600mm centres.
General Substrate Assessment
Assess the stability of the underlying substrate prior to the commencement of work.
Surfaces to be coated including existing repair materials must be firmly fixed.
Dimensional Stability
All factors which may affect the subsequent performance of the area, e.g. saturated insulation, failed structural elements etc. must be removed, repaired or replaced.
Falls
A design fall of minimum 1:40 is recommended in order to ensure a constructed fall of minimum 1:80 is achieved. The integrity of the Bauder LiquiTEC Balcony, Walkway & Terrace System will not be affected if applied to zero pitch, but it is essential that any areas of backfalls or deflection are levelled prior to installing the system.
Surface Moisture
The surface must be dry prior to overlay with the Bauder LiquiTEC Balcony, Walkway & Terrace System.
Theoretical Check
The surface temperature must be higher than the dew point (this can be calculated).