Maintenance and care
The Bauder LiquiTEC system itself is designed to avoid the requirement for regular maintenance as far as possible. However, all flat roofs should be inspected twice annually (Spring and Winter) in order to keep the roof in good condition and determine any problems in their early stages.
General maintenance items
- Remove any debris from the deck area, and all items which could potentially cause damage to the system.
- Check and clean outlets, drainage points, gutters, downspouts etc. and ensure that all rainwater goods are working effectively.
- Carefully remove any plant growth.
- Check all details visually to ensure a sound bond to substrate.
- Check the installed System for any signs of mechanical or chemical damage.
- Check the soffit where visible for evidence of water ingress, wet patches, water staining etc.
- Check other building components e.g. balustrades, surface mounted details, walls, threshold details etc. for soundness.
- Any observations that require attention to the installed Bauder LiquiTEC System should be reported to the Bauder Approved Contractor that installed the system.
Repairs
- Areas of mechanical damage should be repaired by the original installer as soon as possible after they become evident.
- The Bauder approved contractor should consult Bauder Limited for approved repair methods.
Additions and removals
Prior to additions or removals taking place which may affect the integrity of the installed Bauder system, Bauder Limited to be contacted for approved methods.
General protection
Where treated areas are likely to suffer damage or contamination from other trades during subsequent or other works, suitable precautions should be taken to protect the installed system.
Cleaning methods:
Pressure washing
- Manually brush anyway any loose particles, general dust, dirt etc.
- Ensure all outlets, drainage points, gutters and downspouts are clear and free from any blockage.
- Apply a cold or warm (≤50°C) water pressure wash with approved detergent in solution.
- The head of the water lance should be kept at least 500mm away from the surface at all times and the pressure should be restricted to less than 1500psi.
- Preferably leave the detergent solution on the surface for approximately 15 minutes.
- For stubborn areas of dirt, gently brush or mop the surface after the detergent has been applied.
- Rinse the surface with clean, cold water. The head of the water lance should be kept at least 500mm away from the coated surface at all times and the pressure should be restricted to less than 1500psi.
- Squeegee excess water from the surface to outlets, gullies etc.
Manually washing down
- Manually brush away any loose particles, dirt, dust etc.
- Mop the area to be treated with a solution of warm water and approved detergent. For stubborn areas of dirt, gently brush the surface while it is still wet. Care should be taken to only use mop heads that will not be shredded by the quartz surface.
Important notes for all cleaning methods:
- Water temperature should not exceed 50°c.
- Only detergents or degreasants approved by Bauder Limited should be used.
- Cleaning methods should not allow water to penetrate behind the waterproofing.
- Cleaning methods and materials not in accordance with Bauder guidelines may affect any warranty.
De-Icing
- De-icing products which can potentially lead to steel corrosion should not be used unless substrates are fully protected and waterproofed.
- De-icers which dissolve and do not leave an unsightly, dirty residue on the walkway, balcony or terrace areas are recommended.
- Bauder walkway, balcony and terrace systems are resistant to common de-icing materials including:
- Rock salt (white preferable)
- Sodium acetate based de-icers
- Potassium Acetate based de-icers
- Calcium chloride flakes
- Prilled Urea