Dismantling

6.1 Removing safety pins

To dismantle a disconnected photovoltaic module, all 4 safety pins 1 must first be removed.

To do this, remove the safety pins 1 using a long, flat screwdriver.

6.1.2

Please note that the safety pins are no longer re-usable after they have been removed and should be recycled appropriately. (see 7.1)

6.1.3

6.1.4

⚠️ Warning
DANGER! Disconnect the electrical connections!

Before the dismantling of photovoltaic modules and/or the BauderSOLAR mounting system, all electrical connectors must be disconnected by a trained operative. For the safe execution of the dismantling processes, at least 2 operatives should be in attendance.

6.2 Removing a PV module

There is an active clamping pressure from the lower terminals on the photovoltaic module, which must be overcome.

Ensure a secure stance to prevent slipping or falling or damage to the module.

The PV module is clamped between the lower 1 and upper terminals 2 of the mounting unit.
6.2.1

6.1.3

The module clamping is therefore hidden under the module.

The clamp attachment is under tension from the compression springs of the lower terminals. It is therefore essential to carry out a controlled removal process.

⚠️ Warning
Risk of damage to the module frame due to angle of removal!

It is essential to remove the photovoltaic modules as described above at a flat angle on the supporting structure.

Due to the leverage effect, if removed incorrectly there is a risk that the bridge of the module frame will bend permanently, or the clamping hooks will break off.
⚠️ Warning
RISK OF CRUSHING!

Risk of crushing when pulling on the module frame. Use protective gloves to reduce mechanical hazards.

Lift the photovoltaic module out of the stop surfaces 5.

Holding the photovoltaic module in the middle of the frame, pull it back in the angle of inclination of the main structure (12°) only so far that the module frame is just released from the hooks of the upper terminals 3.

6.2.4

6.2.5

Slide the module at a flat angle until the bottom edge of the module hits the stop surfaces on the mounting unit 4, just above the upper terminals.

Be sure to release the photovoltaic module carefully.

6.3 Removing the substructure

To dismantle the substructure, first open the bayonet locks 1 90° by turning to the left 2 and then pull the bayonet out of the baseplates 3.

6.3.1

6.3.2

6.3.4

Note: the main structures are no longer secured by the membrane sleeve on the roof.

Lift the mounting units from the baseplate 4.

6.3.5

Note: The mounting units are stackable for transport 5 up to a maximum height of 24 pieces.

6.4.1

Recycle the bayonet locks and mounting units appropriately. (See 7.1)


6.4 Removing the welding sleeve and base plate

To remove the base plate 1 from the roof surface, the welding sleeve made of bitumen or single-ply material must be expertly detached from the roof waterproofing with a sharp blade 2 and completely removed 3.

6.4.2

6.4.3

Dispose of according to information detailed in 7.1.

6.5 Dismantling the mounting unit components

When dismantling the mounting unit for disassembly into the individual components, proceed as follows:

Open spring shaft on the lock to 45° 1.

Next, pull spring shaft with the retracted compression spring out of the mounting unit 2.

Then pull the module clamp out of the guide of the mounting unit 3.

6.5.1

Repeat the process of removing the second spring shaft.

Separate and sort the module clamps and compression springs and recycle appropriately. (See 7.1)


6.6 Removing the module clamps

Upper module clamp 1 can be removed from the mounting unit by means of a hammer tool 2 striking the module clamp until it detaches and falls down through the main structure 3.

Repeat the process of removing the second module clamp.

Note: the module terminals and the main structure are no longer reusable after removal and should be recycled. (See 8.1)

6.6.3

⚠️ Warning
Clamp fastening under compressive stress!

The compression spring is under tension. Pay attention to the compressive stress during removal!
⚠️ Warning
RISK OF CRUSHING when removing the module clamp!

Risk of injury. Wear work gloves and proceed carefully when removing.