Cellular Glass Inverted Insulation

BauderGLAS Inverted Insulation is for use in conjunction with relevant Bauder Waterproofing Systems and exclusively within Inverted Roof Systems.


BauderGLAS Inverted Insulation can be used as a single or double insulation layer application, in which the top layer is always BauderGLAS Inverted Insulation. It is then overlaid with ballast, paving or extensive green roofs. Alternate finishes will require Bauder Technical approval.

BauderGLAS Inverted Insulation is to be used in conjunction with Bauder JFRI WFRL (Water Flow Reducing Layer), which is laid over the insulation system, and beneath the roof finishes.

Typical build up

  • Paving
  • Paving Support Pads (Specification Specific)
  • Bauder JFRI WFRL
  • BauderGLAS Inverted Insulation
  • BauderGLAS T3+ (used in two-layer systems)
  • Bauder Waterproofing System
  • Screed to falls (if required, not shown)
  • Deck to falls (not shown)

Page 35_1

  • All decks under a BauderGLAS Inverted Insulation System should be designed to comply with BS 6229:2018 with a minimum fall of 1:80. BauderGLAS Inverted Insulation can be used in zero falls applications when designed to comply with the appropriate paragraph in BS6229:2018.
  • Roof falls (as required) and drainage paths should be checked prior to BauderGLAS Inverted Insulation installation to eliminate ponding and the subsequent risk of silt build up, stresses in freezing conditions and to reduce water entry in the event of a failure in the roof waterproofing layer. BauderGLAS Inverted Insulation System is designed for use upon buildings with an internal temperature of 5˚C or higher.
  • In the case of a double layer insulation design, the thickness of the base and top layer should be in accordance with a Bauder Project Specification.
  • The flatness and the general conditions of the substrate are important criteria when using BauderGLAS Inverted Insulation. Bauder Technical Department can be consulted for further guidance on suitability of substrates. Under a straight edge (reference) length of 2 m, the deviation should be less than 5 mm or 3 mm under a straight edge (reference) length of 0.6 m. For further guidance on the suitability of substrates please contact Bauder Technical.
  • Installers of the product must take care not to damage the roof waterproofing, protection layers will be outlined in the Bauder Project Specification.
  • If gravel is to be applied as the ballast, use of rounded gravel is then mandatory as well as a ballast bearing drainage layer. e.g. Bauder PLT10 or Bauder SDF Mat.
  • The ballast layer must be installed to prevent wind uplift and provide complete protection to the WFRL from UV degradation.
  • Ballast design such as gravel or paving should meet the regulations for wind uplift.
  • Gravel ballast (rounded low fines of nominal size 16 mm to 32 mm) should be washed and laid to a minimum thickness of 50 mm.
  • Care must be taken to ensure that upgraded/refurbished roofs are capable of carrying the increased load and depth of the installed system.
  • Adequate measures need to be taken during installation to prevent any damage of the insulation top coating, any damage must be repaired with BauderGLAS Inverted Insulation Repair Kit.
  • Point loads need to be avoided at all times during the installation and specifically when installing the Bauder JFRI WFRL, drainage membrane, pedestals, ballast etc. Where required a protective foot or crawl board must be used to distribute the loads on top of the BauderGLAS Inverted Insulation during the installation of the Bauder JFRI WFRL and subsequent finishes.

Main System Components

Page 38_2

BauderGLAS T3+ Base Layer
BauderGLAS Inverted Insulation

BauderGLAS T3+ insulation (picture 1) This product is only used in the base layer of a 2-layer system and is restricted to a 200mm maximum thickness.

BauderGLAS Inverted Insulation (picture 2) can be used as a single layer but is always the top layer in the system, coating facing upward, colour grey. The coating shade varies in each batch and therefore cannot be specified or guaranteed. The grey coating is pale and becomes darker when wet, returning to its original colouring as it quickly dries.

Both products are 600 x 450mm. Thicknesses are determined by the u value requirement for the roof system and can be found in the Bauder Project Specification.

BauderGLAS Inverted Insulation System (Single and Two layer) Build Up Options

BauderGLAS Inverted System Non-Combustible Insulation on a Continuous Support

One layer system

  • Ballast
  • Drainage composite layer (eg: Bauder PLT10)
  • Bauder JFRI WFRL
  • BauderGLAS Inverted Insulation
  • Bauder Waterproofing
  • Deck to falls (not shown)

Page 38_3

One layer system

  • Paving (by others)
  • Bauder Pedestals
  • Bauder JFRI WFRL
  • BauderGLAS Inverted Insulation
  • Bauder Waterproofing
  • Deck to falls (not shown)

Page 39_1

Two layer system

  • Ballast
  • Drainage composite layer (eg: Bauder PLT10)
  • Bauder JFRI WFRL
  • BauderGLAS Inverted Insulation
  • BauderGLAS T3+
  • Bauder Waterproofing
  • Deck to falls (not shown)

Page 38_3

Two layer system

  • Paving (by others)
  • Bauder Pedestals
  • Bauder JFRI WFRL
  • BauderGLAS Inverted Insulation
  • BauderGLAS T3+
  • Bauder Waterproofing
  • Deck to falls (not shown)

Page 40_1

Application

Substrate (Deck)

The substrate must be created as per BS 6229:2018 Section 4.4, Deflection and Back Falls must be removed prior to waterproofing and BauderGLAS Inverted Insulation installation. The flatness and the general conditions of the substrate are important criteria when using BauderGLAS Inverted Insulation.

Prior to the BauderGLAS Inverted Insulation being installed the waterproofing must be cleaned of all debris. This careful preparation will result in a stable and rigid insulation build up.

BauderGLAS Inverted Insulation can be used with 3 of Bauder’s Waterproofing System’s, namely Hot Melt, Reinforced Bitumen Systems and LiquiTEC Cold Applied Liquid.

The Bauder Waterproofing system chosen should be installed as per manufacturer’s recommendations. BauderGLAS Inverted Insulation must be evenly supported on the substrate. When working with 2 layers of insulation, the BauderGLAS Inverted Insulation is entirely supported by the base layer of BauderGLAS T3+ slab and must be laid correctly and evenly supported on the deck/substrate.

BauderGLAS T3+ slab and BauderGLAS Inverted Insulation are loose laid.

If side and end laps are required within the top layer of the chosen Bauder Waterproofing system then the layer of insulation in contact with the waterproofing can be adapted by abrasion, so that the BauderGLAS Inverted Insulation rests flat on the waterproofing either side of side and end laps. Bauder will state the method to be used within the Bauder Project Specification to achieve continuous contact with the deck/substrate surface and if an isolation layer is required to protect the waterproofing from damage by the BauderGLAS Insulation.

Page 41_1

Single layer system

  • Make sure to install the BauderGLAS Inverted Insulation with staggered joints. The stagger should be a minimum of 150mm.
  • Infill pieces must have a minimum width of 150mm.
  • To maximise insulating performance ALL abutments and insulation joints MUST be tightly butted up. If necessary re-measure, replace or cut/sand down and re-install any insulation which is not fitting correctly. Also ensure BauderGLAS Inverted Insulation is tight with no gaps where it meets rooflights, walls, edge details and other services which perforate the roof deck.

Two layer system

  • Each insulation layer is offset relative to the other, (see pictures 3 & 4). The best staggered overlap is 150mm or more.
  • Infill pieces must have a minimum width of 150mm.
  • The base layer, BauderGLAS T3+ slab should always be installed with staggered joints, with minimum stagger of 150mm (Picture 3 dotted line).
  • The insulation top layer, BauderGLAS Inverted Insulation, should always be installed with staggered joints, with minimum stagger of 150mm (picture 3 black line)
  • To maximise insulating performance ALL abutments and insulation joints MUST be tightly butted up. If necessary re-measure, replace or cut/sand down and re-install any insulation which is not fitting correctly. Also ensure BauderGLAS Inverted Insulation is tight with no gaps where it meets rooflights, walls, edge details and other services which perforate the roof deck.

See Picture 3: blue dotted line = BauderGLAS T3+ layer, full lines = BauderGLAS Inverted Insulation

Page 41_2

Shaping and adapting the insulation in case of unevenness

BauderGLAS Inverted Insulation is easily trimmed and shaped, therefore if the substrate or abutment is uneven, it’s easy to modify the insulation by abrading / sanding or cutting to fit. The BauderGLAS Inverted Insulation layers must be fully supported upon the substrate with no rocking or movement.

Always use the correct PPE as sanding and cutting of the insulation will create offcuts and dust. To ensure the insulation is sitting correctly in position with closed joints and no rocking or movement, remove offcuts and dust from the area prior to laying the insulation.

Useful tools


Page 42_1

Cutting BauderGLAS Inverted Insulation

Bauder recommends that designated areas are set out on each roof area to limit the spread of debris accumulated in the cutting and abrading processes.

BauderGLAS Inverted Insulation is easy to cut and adjust.

Many contractors will set up a working area with all the necessary marking out and cutting tools; this ensures all the offcuts and dust is in one working area. Regularly clear away the offcuts and dust to maintain a clear and dust free working and installation area.

  • Sanding/abrading is used to make small adjustments.
  • Cutting is used to trim down the insulation to create the staggered layout, and to fit neatly against the adjacent insulation and abutments. To maximise insulating performance ALL abutments and insulation joints MUST be tightly butted together.
  • If necessary re-measure, cut and re-install any insulation which is not fitting correctly.
  • A metal saw or hardpoint timber saw is used for cutting all BauderGLAS insulation.
  • It is important to use a square edge, mark a line (picture 1), and make a clean and straight cut (picture 2). Prepare a robust, flat working surface which fully supports the insulation. This will ensure accurate, safe and easy cutting of the insulation material.

Page 43_1

Cutting the insulation with a saw

  • Make sure the insulation is fully supported and not rocking or moving. Saw on the downstroke, DO NOT saw on the upstroke, this will chip the insulation and surface coating.
  • Carefully saw in a straight line (green) if you do not saw in a straight line (red) you will have additional work to sand the insulation until you have a flat surface.
  • If a diagonal line is to be cut, measure and mark very carefully to ensure the angle is accurate.
  • To ensure the insulation system is closed up tightly, where possible ensure that the factory machined edges of the insulation butt up against each other; and the cut edges are against an abutment such as a parapet, or rooflight etc.

Ensure you saw in a straight line and cut vertically through the insulation. (green, red)

Page 44 _1

The cut side of the BauderGLAS should be to the outside (wall/parapet) to prevent open joints and getting misplacements of the next slabs.

Making holes in BauderGLAS T3+ or BauderGLAS Inverted Insulation

  • To cut round holes through the insulation place the insulation on a flat and stable surface. Select a thin-walled tube with the correct external diameter (Picture 8). Using a rotating motion gradually press the tube through the BauderGLAS (finish as Picture 9). In the case of the BauderGLAS Inverted Insulation always press from the coated side.
  • Large holes should be cut with a saw and neatly sanded to the desired shape.

Page 44_2

Sanding/Abrading BauderGLAS Inverted Insulation after cutting

  • Use a sanding block to shape the underside of the insulation, to ensure a firm and stable contact with the substrate or an abutment.
  • Sanding the edge of BauderGLAS Inverted Insulation, start at the coating and sand with a downwards motion. Do not sand on the upward stroke, since this can possibly chip the insulation and coating (see Picture 10).