Suitable substrates for receiving the Bakor 790-11 system
Manual Sections
Not every form of deck substrate construction is suitable to receive the Bakor System. Listed below are the types considered suitable and also those to be avoided:
Acceptable Substrates
Structural Concrete Deck
With an aggregate mix of sand, gravel and cement with a density of 2,160kg/m³ – 2,400kg/m³, installed with a Wood Float or other acceptable surface finish (see Page 16/17).
The concrete deck should be properly cured. The recommended curing time is 28 days, depending on site conditions and weather it can be possible to install Bakor 790-11 Monolithic membrane onto a concrete deck after only 14 days curing, provided the membrane has successfully passed a Peel Bond strength test (see Peel Bond test instructions).
Fully cured deck will retain 3 – 5% moisture by volume when fully cured.
Deck can be used to create falls as per BS6229:2018.
Lightweight Structural Concrete Deck
With an aggregate mix of expanded shale, clay, slate etc. with a cured density of 1,400kg/m³ – 1,840kg/m³.
The lightweight concrete should have a Wood Float or other acceptable surface finish (see Page 16/17).
The recommended curing time is 28 days depending on site conditions and weather it can be possible to install Bakor 790-11 Monolithic membrane onto a concrete deck prior to this provided the membrane has successfully passed a Peel Bond strength test (see Peel Bond test instructions).
Fully cured deck will retain 5–20% moisture by volume when fully cured.
Deck can be used to create falls as per BS6229:2018.
Concrete Deck Installed into Vented Profiled Metal Deck
With a minimum cured density of 1,400kg/m³ – 1,840kg/m³, to a Wood Float or other acceptable surface finish (see Page 16/17), may have to cure for up to 60 days before proper adhesion is achieved.
Light weight concrete should be installed over a VENTED metal deck.
A bond check MUST be carried out to check for the correct adhesion.
Deck can be used to create falls as per BS6229:2018.
Pre-cast Concrete
Pre-cast concrete is manufactured off site and can come in different formats.
Typically made of structural weight concrete and is generally an excellent substrate to receive Bakor 790-11.
All joints need to be grouted and reinforced.
Screeds may be required to provide falls or level up pre-stressed cambers.
This type of installation still needs to be moisture content checked prior to waterproofing installation by a standard Peel Bond Test.
Screeds (Sand & Cement)
Although acceptable, Bauder discourages the specification of sand and cement screeds for 2 reasons:
- Although reasonable adhesion can be obtained once prepared, they will permit water to track and become absorbed beneath the system in the event that the waterproofing is damaged or breached. This greatly increases the difficulty and expense of finding the point of water ingress, prior to drying out the underlying substrate and carrying out remedial repairs.
- Pure sand and cement screeds can take a long time to dry. Rule of thumb is for every 1mm of screed up to 50mm allow 1 day per millimetre for the drying process. For every millimetre over 50mm allow 2 days per millimetre for the drying process.
The use of additives to speed up the drying process is at the discretion of the Main Contractor/Client, but if contemplated, the type and make of additive should be notified to Bauder to ensure that it will not affect the bonding of our waterproofing.
Falls to comply with BS6229:2018.
Screeds (Self-Levelling)
Self-levelling screeds can be used to eliminate deflection and/or back falls on concrete decks as laid out in BS6229:2018.
They must be compatible with Bakor 790-11.
Compressive strength must be compliant with the load to be placed on it.
To comply with BS6229:2018.
Asphalt / Asphalt Screeds
Roofing Grade Asphalt is an acceptable substrate to install Bakor 790-11 providing that it is clean and primed.
Existing asphalt must be free of all embedded chippings.
Bear in mind that asphalt may permit water to track and become absorbed beneath the system in the event that the waterproofing is damaged or breached.
Exterior Grade Plywood / OSB3
Exterior grade plywood / OSB3 are acceptable decks for the application of the Bakor 790-11 monolithic membrane, provided the correct preparation has been carried out, i.e. fixings counter sunk, joints properly reinforced, & the deck correctly supported to withstand the inverted build-up loading weight.
Adequate structural support is required to limit back falls and deflection and movement between joints.
Tongue and groove jointed boards are ideal.
Must be free of any special chemical treatments or other applications that may affect Bakor 790-11 ability to bond to it.
Exterior Grade Plywood / OSB3 must be protected from rain etc once installed to prevent moisture content rising to unacceptable levels.
Cement Particle Board / Gypsum
Cement particle board/Gypsum is an acceptable deck for the application of the Bakor 790-11 monolithic membrane, provided the correct preparation has been carried out, i.e. fixings counter sunk, joints properly reinforced, & the deck correctly supported to withstand the inverted build-up loading weight.
They must also be certified for use as a structural deck.
Adequate structural support is required to limit back falls and deflection and movement between joints.
Must be free of any special chemical treatments or other applications that may affect Bakor 790-11 ability to bond to it.
Cement Particle Board/Gypsum must be protected from rain etc once installed to prevent moisture content rising to unacceptable levels.
Boards should be certified to be used in a roofing scenario.
CLT (Cross Laminated Timber)
CLT is an acceptable substrate for Bakor 790-11 with modification to the build-up.
Bauder AP1 Access Sheet must be nailed to deck at appropriate centres prior to installation.
Adequate structural support is required to eliminate deflection and back falls.
CLT Panels must be protected from rain etc once installed to prevent moisture content rising to unacceptable levels.
Bauder recommend that the Building Insurer is consulted to approve waterproofing application to this deck type.
Additional Acceptable Substrates (Upstands)
Metal Sheet
Surface must be cleaned of all protective oils prior to Bakor 790-11 installation.
Brickwork
Mortar joints must be flush with brickwork face.
Blockwork
Mortar joints must be flush with brickwork face.
Unacceptable Substrates
Lightweight Insulating Concretes
Concrete made with aggregates such as Perlite, Pumice, Vermiculite will have a very low density and by their very porous make up, will retain a high degree of moisture, often more than 20% by volume even when cured.
This high moisture content can create a problem in achieving a good bond with deck surface.
The heat from the hot applied membrane will tend to “draw” moisture up from within the concrete to the surface causing the membrane to delaminate off the deck.
However, this type of lightweight concrete can be modified with a suitable Latex, Resin, or Polymer treatment to provide a suitable surface onto which Bakor790-11 will adhere satisfactorily.