Construction of concrete deck structures

Techniques for Curing Concrete

It is imperative that the concrete substrate is allowed to cure sufficiently to ensure that it forms the required adhesion with the Bakor 790-11 monolithic membrane.

British Codes of Practice consider that it takes approximately 28 days for concrete to cure properly using the standard methods of curing.

Concrete decks constructed using profiled metal as formwork will take longer to cure and dry and this process can take up to 60 days.

Basically, the curing process (Hydration) is extremely critical during the first few days, when the water tends to rapidly drain or evaporate out of the concrete.

During this time, it is important to reduce the rate of water evaporation as much as possible.

Standard methods to achieve this include:

  • Curing compounds – The most common aid to concrete curing in the UK today (see The Use of Curing Compound section below).
  • Water curing – this is probably the best method but does rely on the concrete being kept continuously wet.
  • Wet coverings – such as Hessian type fabrics, kept continuously wet covering the concrete.
  • Paper sheets – water pervious sheets require to be kept continuously wet when laid over the concrete. Whilst impervious paper requires no additional water, as it prevents the water within the concrete from evaporating too quickly.
  • Plastic Sheets – these form a vapour resistant barrier over the concrete preventing moisture escaping from the concrete. This method is considered highly practical and efficient.

The Use of Curing Compounds

These additives are a popular method of assisting the curing time of concrete, due to their ease of application, and low material cost.

Typically, the liquid type curing compounds tend to form a film on the concrete surface that significantly slows the evaporation rate of retained moisture.

Below is an indicative listing of types suitable for use in conjunction with Bakor 790-11 and also those considered unsuitable:

Acceptable Compounds

  • Sodium Silicate Based Compounds – These compounds when properly applied do not leave a film or residue on the concrete surface, which can affect the bond strength of the Bakor 790-11 monolithic membrane to the concrete surface. These compounds form an insoluble gel within the surface of the concrete deck, retarding evaporation of the mix water gives a dustproof surface.
  • Resin Based Compounds – These form a residue that can take between 45 – 60 days to oxidize and flake off, when exposed to the elements. So long as there is a residue left, the bond between the Bakor 790-11 monolithic membrane will always be questionable. The residue can be removed by brushing down the surface with a wire brush, or washing the concrete with a light solution of muriatic acid or trisodium phosphate (TSP). The concrete is then washed down with water and thoroughly dried.

Resin based curing compounds therefore may be acceptable as a curing method, but only on the proviso that they must be completely removed prior to the application of the Bakor 790-11 monolithic membrane.

Unacceptable Compounds

  • Wax Based Curing Compounds – These cease to be an effective curing compound after about 28 days, but take 90–100 days to fully dissipate when exposed to the elements. The wax residue will weaken the bond of the Bakor 790-11 monolithic membrane, and is also difficult to remove. Therefore wax based compounds are not acceptable.
  • Acrylic Silicate Based Curing Compounds – These form a permanent film on the surface of the concrete, and could prevent the Bakor 790-11 monolithic membrane from forming an acceptable bond with the concrete. These compounds are therefore not acceptable.
⚠️ Warning
The use of any liquid curing compound in conjunction with Bakor 790-11 monolithic membrane must be approved by Bauder Ltd. Please contact our Technical Department on 01473 257671.

Curing compounds not compatible with Bakor 790-11 will likely need to be removed prior to waterproofing installation.