Installation Checking Procedures

During Installation

  • The installer should regularly check that the membrane is being installed to the correct thickness – which is 6mm + the thickness of the access/protection sheet. The simplest method is to use a needle type tyre gauge.
  • Checking the amount of Bakor 790-11 product used against the area installed will also provide a guide. 6.5kg/m2 of material is the nominal coverage rate.

Post Installation

Leak Testing

Immediately prior to installing the landscape, the integrity of the waterproofing system must be independently checked for leaks.

The method of testing should be agreed with the client’s representative; however, our method of choice is the electronic test.

The Electronic Test

This method is considered the quickest and most accurate method of testing, as it accurately locates very small penetrations on main deck areas.

Independent certification is a warranty requirement and a copy of this test certificate must be submitted to Bauder Ltd prior to the issue of the Guarantee.

Additional Localised Testing

It is recognised that the electronic method can be inaccurate when conducted in close proximity to metal objects, such as outlets, & metal upstands.

In these cases a localised flood test against the areas/details to be checked is more accurate and may be done in conjunction with the electronic test method.

Repairs to Damaged Membrane:

  • Bakor 790-11 monolithic membrane can be repaired easily. The access/protection sheet must be removed from around the damaged areas by a margin of at least 300mm.
  • Any dirt or debris must be removed; the hot Bakor 70-11 membrane is poured onto and over the damaged area. The heat from the newly applied repair material will re-activate the existing membrane to reform the monolithic nature of the membrane, by fusing together.
  • A suitable sized patch of access/protection layer is bedded into and over the repaired area.