| Membranes |
| Air and vapour control layer (AVCL) - end laps | 100 mm minimum |
| Air and vapour control layer (AVCL) - side laps | 100 mm minimum |
| Details - lap between AVCL & underlayer | 100 mm minimum |
| Underlayer - end laps | 100 mm minimum |
| Torch-on underlayer - side laps | 80 mm minimum |
| Self-adhesive underlayer - side laps | 80 mm minimum |
| Capping sheets - end laps | 100 mm minimum |
| Capping sheets - side laps | 80 mm minimum |
| Underlayer & capping sheets - all laps to upstands, edge details, flashings, etc. | 100 mm minimum |
| Adhesives and accessories |
| PU tin adhesive bead width | 10-20 mm |
| Bauder Peel Bar - fixed at 150mm centres | 10 mm gap between lengths |
| GRP Trim | 3 mm gap between lengths |
| GRP Trim | cover joints in trim with 200 mm long pads of bitumen membrane, bonded to the trim. |
| Timber hard edge | to be 10 mm less than insulation thickness. |